Clarified supernatant (20 800 rcf, 2 min) was used for metabolite analysis. Residual glucose and fructose were measured enzymatically (Boehringer-Mannheim 1989 ) with volumes adjusted to 100 μl for microtiter plate analysis (Walker et al., 2014 (
link)). A liquid handling robot (Tecan
EVO 150) collected samples for absorbance readings using an
Infinite® 200 PRO microplate reader (Tecan Group Ltd). Samples were diluted 1 in 10, and 1 in 100 for analysis (Walker et al. 2014 (
link)).
Other analyses included nitrogen by spectrophotometry (Dukes and Butzke 1998 ) using the Primary amino acid nitrogen (PAN) kit (
K- PANOPA; Megazyme), and major metabolites (organic acids, glycerol and ethanol) by HPLC (Lin et al. 2020 (
link)).
Data was organized, analyzed and graphed using GraphPad Prism software (versions 8.0.0 and 9.0.0 for Windows; GraphPad Software, San Diego,
www.graphpad.com). Area Under the Curve (AUC) calculations and statistical analysis using One-way Analysis of Variance Analysis (ANOVA) and multiple comparisons testing was also with GraphPad Prism.