Abdominal Ultrasonography for VAT and SAT Measurement
Corresponding Organization : University of Milan
Other organizations : IRCCS Istituto Auxologico Italiano, Istituti di Ricovero e Cura a Carattere Scientifico
Variable analysis
- Probe type (7.5 MHz linear probe and 3.5 MHz convex-array probe)
- Subcutaneous adipose tissue (SAT) thickness
- Visceral adipose tissue (VAT) thickness
- Physician performing the ultrasonography
- Instrument used (Logiq 3 Pro)
- Measurement location (1 cm above the umbilicus)
- Timing of measurement (end of expiration)
- Probe pressure (standardized)
- Each measurement was taken three times, and the mean of the three measurements was entered into the database.
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.