For the 3DCRT arm, treatment was performed as irradiation of the involved vertebral body as well those immediately above and below to a total dose of 30 Gy in 10 fractions, most commonly delivered with 3/4 anteroposterior/posteroanterior beams. Position verification was carried out weekly before radiotherapy by kilovoltage cone-beam CT (kV-CBCT) and before each fraction by orthogonal portal images being compared with digitally reconstructed radiographs (DRR) from the planning CT.
Single-Fraction SBRT vs. Fractionated 3DCRT for Spinal Metastases
For the 3DCRT arm, treatment was performed as irradiation of the involved vertebral body as well those immediately above and below to a total dose of 30 Gy in 10 fractions, most commonly delivered with 3/4 anteroposterior/posteroanterior beams. Position verification was carried out weekly before radiotherapy by kilovoltage cone-beam CT (kV-CBCT) and before each fraction by orthogonal portal images being compared with digitally reconstructed radiographs (DRR) from the planning CT.
Corresponding Organization :
Other organizations : Heidelberg University, University Hospital Heidelberg, Allegheny General Hospital, Heidelberger Institut für Radioonkologie
Variable analysis
- Radiotherapy techniques (helical Tomotherapy, step-and-shoot intensity-modulated radiotherapy, or volumetric-modulated arc therapy)
- Treatment delivery (prescription dose, OAR tolerance doses, and coverage of the planning target volume)
- Custom immobilization using Aquaplast® head masks, vacuum mattresses, and/or Wingstep® arm abduction framework
- Delineation of OARs (including the spinal cord) and the clinical target volume (CTV) on the planning CT with MRI co-registration
- Image guidance performed in all patients by means of megavoltage CT and/or TomoTherapy platforms
- For the 3DCRT arm, treatment performed as irradiation of the involved vertebral body as well those immediately above and below to a total dose of 30 Gy in 10 fractions, most commonly delivered with 3/4 anteroposterior/posteroanterior beams
- Position verification carried out weekly before radiotherapy by kilovoltage cone-beam CT (kV-CBCT) and before each fraction by orthogonal portal images being compared with digitally reconstructed radiographs (DRR) from the planning CT
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!