One hundred milligrams of freeze-dried basil were used to quantify and determine polyphenols using a UHPLC system (Thermo Fisher Scientific, Waltham, MA, USA) equipped with a thermo-stated column (T=25°C, 100 × 2.1 mm, Kinetex 1.7 µm biphenyl, Phenomenex, Torrance, CA, USA) and a quaternary pump (Ultimate 3000, Dionex, Sunnyvale, CA, USA). Mass spectrometry analysis was facilitated by a Q Exactive Orbitrap LC-MS/MS system (Thermo Fisher Scientific, Waltham, MA, USA). Phenolic compound sampling was performed according to the protocol detailed by Pannico et al. (2020) (link). The accuracy and calibration of the instruments used were set and checked using a mixture of reference standards (Thermo Fisher Scientific, Waltham, MA, USA). Data processing and analysis were performed using Xcalibur software, version 3.0.63 (Thermo Fisher Scientific, Waltham, MA, USA), and the results were expressed as µg g–1 dw.
Comprehensive Antioxidant and Polyphenol Analysis
One hundred milligrams of freeze-dried basil were used to quantify and determine polyphenols using a UHPLC system (Thermo Fisher Scientific, Waltham, MA, USA) equipped with a thermo-stated column (T=25°C, 100 × 2.1 mm, Kinetex 1.7 µm biphenyl, Phenomenex, Torrance, CA, USA) and a quaternary pump (Ultimate 3000, Dionex, Sunnyvale, CA, USA). Mass spectrometry analysis was facilitated by a Q Exactive Orbitrap LC-MS/MS system (Thermo Fisher Scientific, Waltham, MA, USA). Phenolic compound sampling was performed according to the protocol detailed by Pannico et al. (2020) (link). The accuracy and calibration of the instruments used were set and checked using a mixture of reference standards (Thermo Fisher Scientific, Waltham, MA, USA). Data processing and analysis were performed using Xcalibur software, version 3.0.63 (Thermo Fisher Scientific, Waltham, MA, USA), and the results were expressed as µg g–1 dw.
Corresponding Organization :
Other organizations : University of Naples Federico II, Agruicultural Research Institute
Variable analysis
- Extraction method (ABTS+, DPPH, FRAP)
- Antioxidant activity (ABTS+, DPPH, FRAP)
- Phenolic compound concentration
- UV-VIS spectrophotometry (Shimadzu, Japan)
- UHPLC system (Thermo Fisher Scientific, Waltham, MA, USA)
- Q Exactive Orbitrap LC-MS/MS system (Thermo Fisher Scientific, Waltham, MA, USA)
- Thermo-stated column (T=25°C, 100 × 2.1 mm, Kinetex 1.7 µm biphenyl, Phenomenex, Torrance, CA, USA)
- Quaternary pump (Ultimate 3000, Dionex, Sunnyvale, CA, USA)
- Mixture of reference standards (Thermo Fisher Scientific, Waltham, MA, USA)
- Positive control: Trolox equivalents
- Negative control: Not mentioned
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!