The concentration of sST2 was determined using a high-sensitivity, second-generation enzyme-linked immunosorbent assay with a detection limit of 2 ng/mL (Presage®ST2, Critical Diagnostics).28 (link) sST2 values above 35 ng/mL have been linked to adverse outcomes in the setting of overt heart failure.18 (link),29 (link) Quantification of hsTnI was performed with an ultra-sensitive immunoassay for cardiac troponin I that utilizes a novel, single-molecule counting technology (Erenna hsTnI, Singulex).30 (link) The limit of detection is 0.2 pg/mL, with an assay range of 0.5 to 70 pg/mL. The 99th percentile value for this assay has not been well-established, but in small studies of normal subjects ranges from approximately 7 pg/mL to 10 pg/mL.30 (link)–32 (link) hsCRP and BNP were measured as previously described.2 (link)GDF-15 levels were measured with a pre-commercial, automated electrochemiluminescent immunoassay on a Cobas e 411 analyzer (Roche Diagnostics). The assay has a limit of detection below 10 ng/L, a linear measuring range up to 20,000 ng/L, and an inter-assay imprecision of 2.3% and 1.8% at GDF-15 concentrations of 1,100 ng/L and 17,200 ng/L, respectively (Roche Diagnostics, data on file). GDF-15 values obtained with the electrochemiluminescent assay correlate closely with the values measured with our previously described immunoradiometric assay33 (link) (r = 0.980, slope 1.049, intercept −136 ng/L, n = 45 samples with GDF-15 concentrations ranging from 567 to 13,334 ng/L). Using the immunoradiometric assay, 1200 ng/L was previously proposed as the upper limit of the reference interval in apparently healthy elderly individuals.33 (link)
Biomarker Measurement in Fasted Participants
Partial Protocol Preview
This section provides a glimpse into the protocol.
The remaining content is hidden due to licensing restrictions, but the full text is available at the following link:
Access Free Full Text.
Corresponding Organization :
Other organizations : Harvard University, Massachusetts General Hospital, Framingham Heart Study, Medizinische Hochschule Hannover
Protocol cited in 13 other protocols
Variable analysis
- None explicitly mentioned
- Concentration of sST2
- Concentration of hsTnI
- Concentration of hsCRP
- Concentration of BNP
- Concentration of GDF-15
- All participants were supine for approximately five to ten minutes prior to phlebotomy
- Blood samples were immediately centrifuged, and plasma and serum were stored at −70°C
- The samples did not undergo any freeze-thaw cycles prior to the performance of the assays
- None explicitly mentioned
- None explicitly mentioned
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!